基于時(shí)步有限元的抽水蓄能電機(jī)瞬態(tài)參數(shù)計(jì)算方法的對比
發(fā)布時(shí)間:2018-02-16 12:47
本文關(guān)鍵詞: 抽水蓄能電機(jī) 場路耦合 時(shí)步有限元 瞬態(tài)參數(shù) 凍結(jié)磁導(dǎo)率法 出處:《電工技術(shù)學(xué)報(bào)》2015年01期 論文類型:期刊論文
【摘要】:為準(zhǔn)確計(jì)算抽水蓄能電機(jī)分別運(yùn)行于發(fā)電及電動(dòng)工況時(shí)的瞬態(tài)參數(shù),本文基于單元電機(jī)建立了抽水蓄能電機(jī)的場路耦合時(shí)步有限元模型。采用包絡(luò)線法得到空載突然三相短路時(shí)電機(jī)的瞬態(tài)參數(shù)(簡稱包絡(luò)線法),同時(shí)用凍結(jié)磁導(dǎo)率法得到空載突然三相短路時(shí)定轉(zhuǎn)子繞組漏抗及電樞反應(yīng)電抗,由各瞬態(tài)參數(shù)定義式得到瞬態(tài)參數(shù)(簡稱凍結(jié)磁導(dǎo)率法)。將凍結(jié)磁導(dǎo)率法計(jì)算值與設(shè)計(jì)值分別代入短路電流解析式中得到短路電流波形,與時(shí)步有限元仿真波形相比,凍結(jié)磁導(dǎo)率法計(jì)算波形與之更為接近。將這兩種瞬態(tài)參數(shù)計(jì)算方法應(yīng)用于實(shí)驗(yàn)室6極反裝水輪發(fā)電機(jī),與實(shí)驗(yàn)結(jié)果對比驗(yàn)證了兩種計(jì)算方法的有效性和可行性。
[Abstract]:In order to calculate the transient parameters of pumped storage motor (Pumped-storage motor), In this paper, a field-circuit coupled time-step finite element model of pumped-storage motor is established based on the unit motor. The transient parameters of the motor are obtained by using the envelope method, and the frozen permeability is also used to obtain the transient parameters of the motor in the case of a sudden three-phase short circuit with no load (abbreviated as the envelope method). The leakage reactance and armature reaction reactance of stator rotor winding and armature reaction are obtained by the method of no-load and sudden three-phase short circuit. The transient parameters are obtained from the definition of each transient parameter (the frozen permeability method for short). The calculation value of the frozen permeability method and the design value are respectively substituted in the short-circuit current analytical formula to obtain the short-circuit current waveform, which is compared with the time-step finite element simulation waveform. The calculation waveform of frozen permeability method is more close to it. The two transient parameter calculation methods are applied to the 6-pole reverse hydrogenerator in laboratory. The comparison with the experimental results shows the validity and feasibility of the two calculation methods.
【作者單位】: 華北電力大學(xué)電氣與電子工程學(xué)院;哈爾濱大電機(jī)研究所;
【基金】:國家科技支撐計(jì)劃資助項(xiàng)目(2011BAF03B02)
【分類號】:TV743;TV34
【參考文獻(xiàn)】
相關(guān)期刊論文 前8條
1 梁艷萍,湯蘊(yùn)t,
本文編號:1515554
本文鏈接:http://www.wukwdryxk.cn/kejilunwen/dianlilw/1515554.html
最近更新
教材專著